You can edit the WipDbSettings.config that is present at
C:\ProgramData\ebiexperts\<WIP/AB/SAM> Web Server\webapp. You need to restart the services for the changes to take effect.
General Settings
Parameter and default value | Explanation |
---|---|
<EcoWebMaxAge>4000</EcoWebMaxAge> | Ecospaces will be discarded when they reach MaxAge seconds (default : 4000 seconds = ~1hour) |
<EcoWebMaxPool>10</EcoWebMaxPool> | Number of databases caches set it greater than the number of expected concurrent users |
CLARIFICATION
Parameter and default value | Explanation | Rename to | Apply to |
---|---|---|---|
ABTimerDelay Default=30000 | Is the time | OK | AB |
ABDelayNextBackup=300000 | OK | AB | |
SamScanTimerInterval=60000 | SAM | ||
Backup_RetentionTimerInterval = 0 | AB | ||
TimerReloadMins=300000 | Time to wait to wait in minutes to test reload have finished. By default its 5 minutes | WIP/AB | |
DefaultTimeoutMin=360 | TRACKER | ||
TrackerServiceTimeInterval=10000 | |||
SyncCacheServiceTimeInterval=10000 | |||
SyncDelServiceTimeInterval=43200000 | |||
MaxProcessorIdleTime=60 |
WIP Specific Settings
Parameter and default value | Explanation |
---|---|
<WipTrashVersion2Keep>3</WipTrashVersion2Keep> | Number to WIP_Trash versions to keep, 0 mean no version kept |
<ReloadQlikViewApplications>false</ReloadQlikViewApplications> | If true will auto reload QlikView apps on checkout |
TimerReloadMins | Time to wait to wait in minutes to test reload have finished. By default its 5 minutes |
AB Specific Settings
Parameter and default value | Explanation |
---|---|
SAM Specific Settings
Parameter and default value | Explanation |
---|---|
Sam_ScanTimerInterval | This timer will scan App for the Reverse Engineer |
SyncDelServiceTimeInterval | The scan interval to scan the whole QMC to detect a deleted application (default : 43'200'000 millis = 12hours) |
0 Comments