Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

You can edit the WipDbSettings.config that is present at

C:\ProgramData\ebiexperts\<WIP/AB/SAM> Web Server\webapp. You need to restart the services for the changes to take effect.

General Settings

Parameter and default value

Explanation

<EcoWebMaxAge>4000</EcoWebMaxAge>

Ecospaces will be discarded when they reach MaxAge seconds (default : 4000 seconds = ~1hour)

<EcoWebMaxPool>10</EcoWebMaxPool>

Number of databases caches set it greater than the number of expected concurrent users

CLARIFICATION

Parameter and default value

Explanation

Rename to

Apply to

ABTimerDelay Default=30000

Is the time

OK

AB

ABDelayNextBackup=300000

OK

AB

SamScanTimerInterval=60000

SAM

Backup_RetentionTimerInterval = 0

AB

TimerReloadMins=300000

Time to wait to wait in minutes to test reload have finished. By default its 5 minutes

WIP/AB

DefaultTimeoutMin=360

TRACKER

TrackerServiceTimeInterval=10000

SyncCacheServiceTimeInterval=10000

SyncDelServiceTimeInterval=43200000

MaxProcessorIdleTime=60

WIP Specific Settings

Parameter and default value

Explanation

<WipTrashVersion2Keep>3</WipTrashVersion2Keep>

Number to WIP_Trash versions to keep, 0 mean no version kept

<ReloadQlikViewApplications>false</ReloadQlikViewApplications>

If true will auto reload QlikView apps on checkout

TimerReloadMins

Time to wait to wait in minutes to test reload have finished. By default its 5 minutes

AB Specific Settings

Parameter and default value

Explanation

SAM Specific Settings

Parameter and default value

Explanation

Sam_ScanTimerInterval

This timer will scan App for the Reverse Engineer
(default 60’000 millis = 1 minute)

SyncDelServiceTimeInterval

The scan interval to scan the whole QMC to detect a deleted application (default : 43'200'000 millis = 12hours)

  • No labels