You can edit the WipDbSettings.config that is present at

C:\ProgramData\ebiexperts\<WIP/AB/SAM> Web Server\webapp. You need to restart the services for the changes to take effect.

General Settings

Parameter and default value

Explanation

<EcoWebMaxAge>4000</EcoWebMaxAge>

Ecospaces will be discarded when they reach MaxAge seconds (default : 4000 seconds = ~1hour)

<EcoWebMaxPool>10</EcoWebMaxPool>

Number of databases caches set it greater than the number of expected concurrent users

WIP Specific Settings

Parameter and default value

Explanation

<WipTrashVersion2Keep>3</WipTrashVersion2Keep>

Number to WIP_Trash versions to keep, 0 mean no version kept

<ReloadQlikViewApplications>false</ReloadQlikViewApplications>

If true will auto reload QlikView apps on checkout

TimerReloadMins

Time to wait to wait in minutes to test reload have finished. By default its 5 minutes

AB Specific Settings

Parameter and default value

Explanation

SAM Specific Settings

Parameter and default value

Explanation

Sam_ScanTimerInterval

This timer will scan App for the Reverse Engineer
(default 60’000 millis = 1 minute)

SyncDelServiceTimeInterval

The scan interval to scan the whole QMC to detect a deleted application (default : 43'200'000 millis = 12hours)